Time Synchronization Profile Compliance TestsVersion 1.0

9 Miscellaneous Tests

9.1 Contents

9.1.1 Client

IrWW2_C_M_ALARM_CONTENTS_1 (Mandatory if the DUT supports Alarm)

1.General Test Steps 1-5

2.Make the DUT transmit an alarm object request (bWatch) using OBEX GET at read-all.

3.Verify that the DUT received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:ALARM and END: ALARM.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

IrWW2_C_M_TIMER_CONTENTS_1 (Mandatory if the DUT supports Timer)

1.General Test Steps 1-5

2.Make the DUT transmit an timer object request (bWatch) using OBEX GET at read-all.

3.Verify that the DUT received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:TIMER and END: TIMER.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

IrWW2_C_M_STOPW_CONTENTS_1 (Mandatory if the DUT supports Stopwatch)

1.General Test Steps 1-5

2.Make the DUT transmit an stopwatch object request (bWatch) using OBEX GET at read-all.

3.Verify that the DUT received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:STOPWATCH and END: STOPWATCH.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

IrWW2_C_M_TSYNC_CONTENTS_1 (Mandatory if the DUT supports Time-Sync)

1.General Test Steps 1-5

2.Make the DUT transmit an Time-Sync object request (bWatch) using OBEX GET at single pull.

3.Verify that the DUT received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:T-SYNC and END: T-SYNC.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

9.1.2 Server

IrWW2_S_M_ALARM_CONTENTS_1 (Mandatory if the DUT supports Alarm)

1.General Test Steps 1-5

2.Make the Tester transmit an alarm object request (bWatch) using OBEX GET at read-all.

3.Verify that the Tester received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

14

Time Synchronization Profile Compliance TestsVersion 1.0

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:ALARM and END: ALARM.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

IrWW2_S_M_TIMER_CONTENTS_1 (Mandatory if the DUT supports Timer)

1.General Test Steps 1-5

2.Make the Tester transmit an timer object request (bWatch) using OBEX GET at read-all.

3.Verify that the Tester received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:TIMER and END: TIMER.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

IrWW2_S_M_STOPW_CONTENTS_1 (Mandatory if the DUT supports Stopwatch)

1.General Test Steps 1-5

2.Make the Tester transmit an stopwatch object request (bWatch) using OBEX GET at read-all.

3.Verify that the Tester received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:STOPWATCH and END: STOPWATCH.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

IrWW2_S_M_TSYNC_CONTENTS_1 (Mandatory if the DUT supports Time-Sync)

1.General Test Steps 1-5

2.Make the Tester transmit an Time-Sync object request (bWatch) using OBEX GET at single pull.

3.Verify that the Tester received the bWatch correctly.

4.Check that there is object stream identifier in the beginning.

5.Check that the bWatch is encapsulated with BEGIN:BWATCH and END: BWATCH.

6.Check that there is the mandatory field VERSION after BEGIN: BWATCH.

7.Check that the information is encapsulated with BEGIN:T-SYNC and END: T-SYNC.

8.Check that the bWatch contains the mandatory fields specified in [IrWW2].

15

Time Synchronization Profile Compliance TestsVersion 1.0

10 Test Result Template

Testing DATE:

Testing Environments

 

DUT(Device Under Test)

Test Tools or System:

 

Product Company:

 

 

 

 

 

Product Model:

Hardware:

 

 

 

 

Product Revision:

 

 

 

Software:

 

Product Sample Serial No.

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

Test Name

Pass/Fail

Comments

IrWW2_C_P_BXX_HINT_1

 

 

IrWW2_C_P_BXX_HINT_2

 

 

IrWW2_C_P_BXX_HINT_3

 

 

IrWW2_C_P_BXX_HINT_4

 

 

IrWW2_S_P_BXX_HINT_1

 

 

IrWW2_S_P_BXX_HINT_2

 

 

IrWW2_C_P_BXX_IAS_1

 

 

IrWW2_C_P_BXX_IAS_2

 

 

IrWW2_S_P_BXX_IAS_1

 

 

IrWW2_S_P_BXX_IAS_2

 

 

IrWW2_C_P_BXX_DEVINFO_1

 

 

IrWW2_S_P_BXX_DEVINFO_1

 

 

IrWW2_C_P_BXX_INFOLOG_1

 

 

IrWW2_S_P_BXX_INFOLOG_1

 

 

IrWW2_C_A_BXX_PUT_1

 

 

IrWW2_C_A_BXX_PUT_2

 

 

IrWW2_C_A_BXX_GET_1

 

 

IrWW2_S_A_BXX_PUT_1

 

 

IrWW2_S_A_BXX_PUT_2

 

 

IrWW2_S_A_BXX_GET_1

 

 

IrWW2_C_S_BXX_PUT_1

 

 

IrWW2_S_S_BXX_PUT_1

 

 

IrWW2_C_S_BXX_GET_1

 

 

IrWW2_S_S_BXX_GET_1

 

 

IrWW2_S_P_BXX_RSP_1

 

 

IrWW2_S_P_BXX_RSP_2

 

 

IrWW2_S_P_BXX_RSP_3

 

 

IrWW2_S_P_BXX_RSP_4

 

 

IrWW2_C_P_BXX_DEL_1

 

 

IrWW2_S_P_BXX_DEL_1

 

 

IrWW2_S_P_BXX_DEL_2

 

 

IrWW2_C_M_ALARM_CONTENTS_1

 

 

IrWW2_C_M_TIMER_CONTENTS_1

 

 

IrWW2_C_M_STOPW_CONTENTS_1

 

 

IrWW2_C_M_TSYNC_CONTENTS_1

 

 

16

Time Synchronization Profile Compliance TestsVersion 1.0

IrWW2_S_M_ALARM_CONTENTS_1

IrWW2_S_M_TIMER_CONTENTS_1

IrWW2_S_M_STOPW_CONTENTS_1

IrWW2_S_M_TSYNC_CONTENTS_1

17

Соседние файлы в предмете Электротехника