Chapter 6 Function Descriptions

FDepth

int32 FDepth(path);

Purpose

Computes the depth (number of component names) of a path.

Parameters

Name

Type

Description

 

 

 

 

 

 

path

Path

Path whose depth you want to determine.

 

 

 

Return Value

int32, indicating the depth of the path, which can contain the following values:

–1

Badly formed path.

0

Path is the root directory.

1

Path is in the root directory.

2

Path is in a subdirectory of the root directory, one level from the

 

root directory.

n–1

Path is n–2 levels from the root directory.

N

Path is n–1 levels from the root directory.

6-59

Using External Code in LabVIEW

Chapter 6 Function Descriptions

FDirName

MgErr FDirName(path, dir);

Purpose

Creates a path for the parent directory of a specified path. You can pass the same path variable for the parent path that you use for path. Therefore, you can call this function in the following two ways:

err = FDirName(path, dir);

/* the parent path is returned in a second path variable */

err = FDirName(path, path);

/* the parent path writes over the existing path */

Parameters

Name

Type

Description

 

 

 

 

 

 

path

Path

Path whose parent path you want to

 

 

determine.

 

 

 

dir

Path

Parameter in which FDirName stores the

 

 

parent path.

 

 

 

Return Value

mgErr, which can contain the following errors:

mgArgErr

A bad argument was passed to the function. Verify the path.

Using External Code in LabVIEW

6-60

www.ni.com

Chapter 6 Function Descriptions

FDisposePath

MgErr FDisposePath(p);

Purpose

Disposes of a path.

Parameters

Name

Type

Description

 

 

 

 

 

 

p

Path

Path you want to dispose of.

 

 

 

Return Value

mgErr, which can contain the following errors:

mZoneErr

Invalid path.

© National Instruments Corporation

6-61

Using External Code in LabVIEW

Chapter 6 Function Descriptions

FDisposeRefNum

MgErr FDisposeRefNum(refNum);

Purpose

Disposes of the specified file refNum.

Parameters

Name

Type

Description

 

 

 

 

 

 

refNum

LVRefNum

File refnum of which you want to dispose.

 

 

 

Return Value

mgErr, which can contain the following errors:

mgArgErr

File refnum is not valid.