Chapter 8

Digital I/O

For 8255-based devices that perform handshaking, such as the DIO-24 or DIO-96, connect all the STB lines together if you are grouping ports for digital input, as shown in Figure 8-2. Connect only the IBF line of the last port in the port list to the other device. No connection is needed for the IBF signals for the other ports in the port list.

STB*

 

Port x 1

 

IBF

 

STB*

 

Port x 2

 

IBF

 

STB*

 

Port x n

External Device

IBF

 

(last port in portList)

 

Figure 8-2. Connecting Signal Lines for Digital Input