When this interface is added, these default nodes are also added to the Model BuilderFluid Properties, Wall, Rotating Wall, and Initial Values. See Rotating Domain, Initial Values, and Rotating Wall in this section for details.

See The Single-Phase Flow, Laminar Flow and Creeping Flow Interfaces

for all the settings.

Note

This interface changes to The Rotating Machinery, Laminar Flow

Interface when the Turbulence model type selected is None.

Tip

Rotating Domain

Use the Rotating Domains feature to set the rotational frequency and direction in The Single-Phase Flow, Rotating Machinery Interfaces. If there is more than one rotating domain, these must not intersect.

D O M A I N S E L E C T I O N

From the Selection list, choose the domains to define the rotating machinery.

R O T A T I N G D O M A I N

 

Select the Rotation axis base point. The default is the origin (0, 0). Then

 

select a Rotational frequencyRevolutions per time or Angular velocity.

 

If Revolutions per time is selected, enter a value or expression in the field

 

(SI unit: 1/s) and select a Rotational directionClockwise (the default)

2D

or Counterclockwise.

 

If Angular velocity is selected, enter an Angular velocity w

 

(SI unit: rad/s).

 

 

T H E S I N G L E - P H A S E F L O W , R O T A T I N G M A C H I N E R Y I N T E R F A C E S | 105