Raytrace Options

Save Data to Disk during Raytrace

During the raytrace, TracePro may save the Exit Surface and Candela data in a binary format (SIM file). One reason for using this option is to minimize RAM consumption during the raytrace. In addition, the data from the Exit Surface SIM file can be recalled from the Simulation File Manager (See “Simulation File Manager” on page 6.58).

Save Ray History to disk

A Ray History table for the Exit surface is generated and saved as a text file for the model. The file name is formed by appending “-rayhistory.txt” to the model name. Data is not written to disk if this option is not selected.

Sort Ray Paths

A set of ray paths for rays absorbed at the Exit surface is generated and saved into a text file for the model. The file name is formed by appending “-raypaths.txt,” to the model name. Data is not written to disk if this option is not selected.

Save Bulk Scatter data to disk

A set of positions and flux values for each bulk scattered ray is generated and saved into a text file for the model. The file name is formed by appending “- scatter.txt,” to the model name. Data is not written to disk if this option is not selected.

Simulation Options for TracePro LC LC

For TracePro LC , Simulation information is set in the Options tab of the Raytrace Options dialog box, as shown in Figure 5.23. The two options let you control what data is saved during a simulation raytrace. To save ray data for an exit surface so that an irradiance map can be generated, check the Collect Exit Surface Data box. To save ray data for candela/intensity plots, check the Collect Candela Data.

Collect Exit Surface Data

Data is collected for the Exit Surface defined by the Exit Surface Property. After the raytrace is complete, irradiance Maps and ray tables can be displayed for the Exit Surface.

Collect Candela Data

Data is collected for rays which are traced beyond the model. After the raytrace is complete Candela Plots can be displayed.