TPA Dc. 2014 BOOK 3_CLIMATE CHANGE
.pdfTotal’s involment in CCS projects worlwide
81 |
Book 3 - GHG |
A TOTAL Project :
CCS pilot project in Lacq-general objectives.
CO2 capture |
|
CO2 transport |
CO2 storage |
|
and injection |
||
|
|
|
|
|
|
|
|
1 - Contribute to a potential climate change mitigation technology
2 - A 30 MWth oxycombustion scheme with CCS
3 - A pilot to validate industrial size CCS schemes worldwide 4 – Total cost = 60 M€, entirely funded by Total
82 |
Book 3 - GHG |
Pilot location:
Total Exploration & Production in France
83 |
Book 3 - GHG |
The Lacq plant - South-West of France
84 |
Book 3 - GHG |
Carbon Capture & geological Storage in the Lacq region
85 |
Book 3 - GHG |
CO2 injection into a depleted gas reservoir
|
Book 3 - GHG |
86 |
Installations for CO2 Capture at Lacq
87 |
Book 3 - GHG |
Boiler revamping
Existing boiler revamping with
CO2 recycling
40 t/h ot steam 60bar/450°C
(30 MWth) to HP steam network
|
Oxygène |
|
Combustible |
? |
Fumées d’oxy-combustion |
Eau d’alimentation |
|
|
Vapeur produite |
|
|
ALSTOM in change of boiler revamping study
Air Liquide developing and providing oxyburners
1MW prototype tested
4 x 8 MWth required
204 t/day oxygen required
88
Ventilateur de |
|
recycle des fumées |
Cheminée |
|
Registre
Traitement des fumées
Ventilateur booster vers traitement de fumées
Book 3 - GHG
Lacq CCS oxycombustion basic process
Combustion using pure oxygene releases flue gas with a high concentration of CO2 and water vapor
The flue gas is purified and dehydrated. The wet CO2 (concentration of 90 to 93%) is compressed at 27 bar then dried for transport (27 km)
The CO2 is then compressed at a pressure of over 40 bar before being reinjected to a depth of 4500 m into the Rousse reservoir
Rousse reservoir has already demonstrated its integrity for several million years
89 |
Book 3 - GHG |
CO2 injection at Lacq: volume and pressure of CO2 Pre-project estimates
90 |
Book 3 - GHG |