Добавил:
Upload Опубликованный материал нарушает ваши авторские права? Сообщите нам.
Вуз: Предмет: Файл:
111 / da-42NGnew / DA42-NG-AFM-r1.pdf
Скачиваний:
203
Добавлен:
20.04.2015
Размер:
2.96 Mб
Скачать

DA 42 NG AFM

Abnormal Operating

Procedures

4B.7 FAILURES IN HYDRAULIC SYSTEM

4B.7.1 CONTINUOUS HYDRAULIC PUMP OPERATION

1.Landing gear indication lights . . . . . . . . . . . . check

2.Prepare for manual landing gear extension. Refer to Section 3.8.2 - MANUAL

EXTENSION OF THE LANDING GEAR.

NOTE

The landing gear might extend as the hydraulic system pressure decreases. Consider for higher aerodynamic drag, resulting in degraded flight performance, increased fuel consumption and decreased range.

Unscheduled maintenance action is required after landing.

END OF CHECKLIST

Doc. No. 7.01.15-E

Rev. 1

18-Feb-2009

Page 4B - 27

 

 

 

 

Abnormal Operating

DA 42 NG AFM

Procedures

4B.7.2 HYDRAULIC PUMP FAILURE

1.Landing gear indication lights . . . . . . . . . . . . check

2.Prepare for manual landing gear extension. Refer to Section 3.8.2 - MANUAL

EXTENSION OF THE LANDING GEAR.

NOTE

The landing gear might extend as the hydraulic system pressure decreases. Consider for higher aerodynamic drag, resulting in degraded flight performance, increased fuel consumption and decreased range.

Unscheduled maintenance action is required after landing.

END OF CHECKLIST

Page 4B - 28

Rev. 1

18-Feb-2009

Doc. No. 7.01.15-E

 

 

 

 

DA 42 NG AFM

Abnormal Operating

Procedures

4B.8 STARTING ENGINE WITH EXTERNAL POWER

4B.8.1 BEFORE STARTING ENGINE

1.

Pre-flight inspection . . . . . . . . . . . . . . . . . . .

complete

2.

Passengers . . . . . . . . . . . . . . . . . . . . . . . . .

instructed

NOTE

Ensure all the passengers have been fully briefed on the use of the seat belts, adjustable back rests (if installed), doors and emergency exits and the ban on smoking.

3.

Rear door . . . . . . . . . . . . . . . . . . . . . . . . . . .

closed and locked

4.

Front canopy . . . . . . . . . . . . . . . . . . . . . . . . .

position 1 or 2 (“cooling gap”)

5.

Rudder pedals . . . . . . . . . . . . . . . . . . . . . . .

adjusted; if manual pedal

 

 

adjustment is installed, verify

 

 

proper locking

6.

Safety harnesses . . . . . . . . . . . . . . . . . . . . .

all on and fastened

7.

POWER lever . . . . . . . . . . . . . . . . . . . . . . . .

check IDLE

8.

Parking brake . . . . . . . . . . . . . . . . . . . . . . . .

set

9.

AVIONIC MASTER . . . . . . . . . . . . . . . . . . .

check OFF

10. GEAR selector . . . . . . . . . . . . . . . . . . . . . . .

check DOWN

11. VOTER switch . . . . . . . . . . . . . . . . . . . . . . .

check AUTO

12. ALTERNATORS . . . . . . . . . . . . . . . . . . . . . .

check ON

13. ELECT. MASTER . . . . . . . . . . . . . . . . . . . . .

check OFF

14. ENGINE MASTER . . . . . . . . . . . . . . . . . . . .

check OFF

15. PROPELLER . . . . . . . . . . . . . . . . . . . . . . . .

check clear

16.

External power . . . . . . . . . . . . . . . . . . . . . . .

connect

CONTINUED

Doc. No. 7.01.15-E

Rev. 1

18-Feb-2009

Page 4B - 29

 

 

 

 

Abnormal Operating

DA 42 NG AFM

Procedures

CAUTION

When switching the External Power Unit ON, the electrically driven hydraulic gear pump may activate itself for 5 to 20 seconds in order to restore the system pressure. Should the pump continue to operate continuously or periodically, terminate flight. There is a malfunction in the landing gear system.

NOTE

When switching the External Power Unit ON, all electrical equipment, connected to the LH and RH main buses is powered.

17. G1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . wait until power-up completed. Press ENT on MFD to acknowledge.

NOTE

The engine instruments are only available on the MFD after item 17 has been completed.

END OF CHECKLIST

Page 4B - 30

Rev. 1

18-Feb-2009

Doc. No. 7.01.15-E

 

 

 

 