c) A set of samples are taken from a process in one instant in time. The samples are all from a very short period of production time.

d)

UCL

R

LCL

trends of downward points

too many points between +2 and +3 σ

8.May as well use a3 and a4, but other methods could be used. X = 148.3125, s = 9.0459, a3 =

.3900 (skewed to right, positive direction), a4 = 1.958 indicates mesokurtic.

9.

154.26

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UCL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

148.31

X

142.36

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCL

41.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UCL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22.75

R

3.56

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LCL

4.11 QUALITY CONTROL FORMS

1. Frequency Distribution Analysis Sheet

page 51