- •Version 2.06
- •Introduction ............................................................................................................................................................. 4
- •10 Simple network management protocol (snmp) .............................................................................................. 106
- •Introduction
- •1.3.10 New Feature for version 1.97
- •1.3.11 New Features (since version 1.97)
- •1.3.12 New Features since version 2.03
- •1.3.13 Alarm Tone New Features since version 2.04
- •1.3.14 New Features since version 2.05
- •3.11.1 Analog Statistics
- •3.11.2 Battery Log
- •3.11.3 Event Log
- •3.11.4 Data Logging
- •Verify action and
- •4.3.4.5
- •4.3.4.6
- •4.3.4.7
- •4.3.4.8
- •4.3.4.9
- •4.3.4.10 Canceling bt Mode
- •4.3.4.11 Battery Discharge Test Completion
- •4.3.4.12 Remote bt Mode
- •Inventory Update
- •4.10.1 Sntp (Simple Network Time Protocol)
- •In this example, the Time Zone
- •Virtual Numeric Keypad
- •6.3.2.1
- •6.3.2.6
- •6.3.2.7
- •6.3.2.8
- •6.3.2.9
- •6.3.2.10 Eq Timeout
- •6.3.2.15 Module Start Delay
- •6.3.2.16 System Start Delay
- •6.3.3.4
- •6.4.1.1
- •6.4.1.2
- •6.4.1.3
- •6.4.5.1
- •6.4.5.2
- •Interval
- •6.4.5.3
- •6.4.5.4
- •6.4.6.1
- •6.4.6.2
- •6.4.6.3
- •6.4.6.4
- •6.4.7.1
- •6.4.8.4
- •6.4.8.5
- •6.4.8.6
- •6.5.3.1
- •6.5.3.2
- •Via a virtual numeric keypad
- •6.5.3.3
- •6.5.3.4
- •6.5.3.5
- •6.5.3.6
- •6.5.3.7
- •Voltage Alarms
- •6.5.3.8
- •Invalid Device Firmware
- •Improper Controller Shutdown
- •Invalid Battery Voltage
- •6.5.3.9
- •6.5.3.10 Custom Alarms (1-20)
- •6.5.3.11 Converter Alarms
- •6.6.1.1
- •6.6.2.5
- •6.6.2.6
- •6.6.2.7
- •6.6.2.8
- •6.6.2.9
- •6.6.2.10 Timers
- •6.6.2.11 Adio Signals
- •6.6.3.1
- •6.6.3.2
- •6.6.3.3
- •6.6.3.4
- •6.6.3.5
- •6.6.3.6
- •6.7.1.1
- •6.7.4.1
- •Ip Information
- •Ip Address (“Ethernet” per web interface)
- •Via a virtual numeric keypad
- •6.8.3.1
- •6.8.4.1
- •6.10.1 Retrieve Logs
- •6.10.2 Manage Configuration File
- •6.10.2.1 Printing Custom Site Configuration
- •6.10.3 Manage Dynamic (Editable) Text Files
- •6.10.4 Manage Language Files
- •6.10.5 Retrieve Diagnostic File
- •6.11.1 Change Password
- •8.1.1.1
- •Ip Information
- •8.1.3.1
- •8.1.3.2
- •Ip Address
- •Internal Modem Support
- •8.3.4.1
- •8.3.4.2
- •8.3.4.3
- •Internal Modem
- •9.2.3.1
- •10.1.1 Outline of the snmp Protocol
- •10.1.2 Underlying Communication Protocols
- •10.1.3 Typical udp Transport
- •10.1.4 Variable Binding (VarBind)
- •10.3.1 Snmp Multiple Community Names
- •10.3.2 Snmp Trap Recovery
- •10.3.3 Event Notification Destination – Multiple snmp and smtp Destinations
- •10.3.3.1 Master snmp Destination
- •10.3.3.2 Inform Settings (Trap Acknowledge)
- •Inform should never be
1.3.12 New Features since version 2.03
The following changes/updates have been incorporated into version 2.04 of the CXC software:
The battery log will be closed off when 96 hours has elapsed since the start of the recharge cycle. This is
in addition to the existing functionality that closes off the log when the returned AH reaches 115% of the
rated capacity during the recharge cycle.
Improved response of charge current control when lithium-ion batteries are installed. Lithium-ion batteries
are detected by scanning the battery information and looking for the keyword “lithium” or “li-ion” in the
model comment fields.
The rectifier start delay algorithm now allows a setting of 0 s instead of the former minimum of 1 s.
0350046-J0 Rev C
Page 8 of 127
Visit the Alpha website at www.alpha.ca for the latest manual and product downloads
1.3.13 Alarm Tone New Features since version 2.04
The following changes/updates have been incorporated into version 2.05 of the CXC software:
Diagnostic Capture – in the event of certain types of CXC crashes or “Improper Shutdowns”, the software will
now capture a diagnostic log of the system as it is shutting down. This log can be downloaded from the CXC
webpages (Under Logs and Files -> Retrieve Diagnostic File) and sent to the Alpha technical support team. See
section 6.10.5 for more information on the diagnostic file.
SNMP Trap – a new feature has been added to allow users to set the value of a Custom Signal over SNMP. This
custom signal can then be used in alarms and equations, and therefore trigger relays to toggle. It should be noted
that the CXC will not maintain the value of a signal that has been set by SNMP during a reset. In order to
accommodate customers who are already using the previously defined 10 Custom Signals, 10 additional Custom
Signals were added, raising the total number of Custom Signals to 20. See section 6.6.2.5 for more information
on Custom Signals.
Updates to SNMP communities names and destination fields – community and destination names can now be 31
characters long. In addition, 10 destination and community strings are allowed instead of 8. See section 10 for
more information on SNMP.
Email address maximum length fixed – previously there was an bug which caused email addresses longer than
31 characters not to work for event notification. The CXC now allows email addresses up to 64 characters (63 + 1
for string termination character) as was intended. See section 10.3.3 for more information about sending
notification emails from the CXC.
Improper Shutdown caused by RS485 buffer – a bug fix. In previous versions of the CXC, a problem with the
RS485 interface caused occasional “Improper Shutdowns” of the unit. This problem has been solved in this
release.
Update from Argus logo to Alpha logo.
A new bootloader, version 2.01, was released with CXC 2.05. Upgrade to this bootloader is recommended as it
contains various bug fixes. The bootloader can be upgraded via the CXC webpages by navigating to the
“Controller -> Upgrade Bootloader” menu and following the instructions there.