ELSA SPRAY MODELLING

Chapter 23

STAR Set-up in pro-STAR

 

 

 

Figure 23-46 Nozzle scalar definition

Setting up analysis controls

The ELSA model is a complex simulation that requires tighter residuals and lower under-relaxation settings, to be defined in this section. You must also specify the run’s post-processing requirements.

Define the solution method, differencing scheme and scalar residual tolerance:

In the pro-STAR Model Guide, select Analysis Controls > Solution Method

(see Figure 23-47) and set the panel parameters as follows:

Maximum Residual Tolerance 1e-05

Maximum Number of Corrector Stages 500

Under-Relaxation for Pressure Correction 0.3

Click Apply

23-36

Version 4.20

Chapter 23

ELSA SPRAY MODELLING

 

STAR Set-up in pro-STAR

 

 

Figure 23-47 Solution Method panel

In the pro-STAR Model Guide, select Analysis Controls > Primary Variables (see Figure 23-48)

In the Differencing Scheme tab, set the Differencing Scheme to UD for U-Momentum, V-Momentum and W-Momentum

Set Differencing Scheme to UD for Turbulence KE and Turbulence Diss.

Click Apply

Figure 23-48 Differencing Schemes panel

Version 4.20

23-37

ELSA SPRAY MODELLING

Chapter 23

STAR Set-up in pro-STAR

 

 

 

In the pro-STAR Model Guide, select Analysis Controls > Additional Scalars (Controls) (see Figure 23-49)

In the Scalar table, select Scalar Number 48 and set the Residual Tolerance to 1e-12

Click Apply

Select Scalar Number 49 and set the Residual Tolerance to 1e-12

Click Apply

Figure 23-49 Scalar residual tolerances

Specify the analysis controls for post-processing:

In the pro-STAR Model Guide, select Analysis Controls > Analysis Output

Select the Post tab (see Figure 23-50) and set the panel parameters as follows:

Output Frequency 100

Backup Frequency 600

Click Apply

23-38

Version 4.20

Chapter 23

ELSA SPRAY MODELLING

 

STAR Set-up in pro-STAR

 

 

Figure 23-50 Analysis Output > Post panel

Select the Transient tab (see Figure 23-51) and set the panel parameters as follows:

Starting at time (degCA) 680

Output interval (degCA) 2

In the displayed list of available output data, select LIQM_ELSA and click the Post check box

Repeat the previous step for the following variables:

LIQV_ELSA

Temperature

Click Apply

Version 4.20