ELSA SPRAY MODELLING

Chapter 23

STAR Set-up in pro-STAR

 

 

 

Figure 23-51 Analysis Output > Transient tab

Enter the following commands in pro-STAR’s I/O window to set the special switches and constants required for an ELSA analysis:

Switch 127, which switches off diffusion at inlets for all scalars:

SWITCH, 127, ON

Real Constant 23, which sets the supplied value as the maximum permissible void fraction

RCONSTANT, 23, 1e-10

Real Constant 196, which deletes parcels whose mass is less than the supplied value

RCONSTANT, 195, 1e-15

Adding extended data for the ELSA model

The ELSA model is controlled by keywords and parameter values specified in the Extended Data section of the problem file. For more information on the required keywords and values see Chapter 19, “Extended Data” in the STAR-CD Supplementary Notes volume.

23-40

Version 4.20

Chapter 23

ELSA SPRAY MODELLING

 

STAR Set-up in pro-STAR

 

 

Edit the Extended Data section:

From the menu bar, select Utility > Extended Data

Enter the following text at the bottom of the Extended Data panel (see Figure 23-52)

BEGIN ELSA_MODEL 1 1

iSigmaModel 1 surf_tens 2.48679d-2 time_inj4 3.0d-1 crit_nap 0.01d0 Pbig 2.0d19 drmin 1.0d-10 nparcel 1.0

elsaEL_forced minliq1 0.01d0 minliq2 1.0d-6 elsaST_EXP

elsaOmega_LIMIT 1.0d-8

END ELSA_MODEL

Click Save followed by Close