page 412

often created in other locations.

24.1.1.7 - Floating Point Memory

This can hold real values with fraction in the range of +/-1.1754944e-38 to +/-3.4028237e38.

These values are always limited to 7 digits of accuracy.

Floating point memoy is stored in F8:xx by default.

24.2 INSTRUCTION TYPES

• There are basic categories of instructions, Basic (discussed before)

-relay instructions

-timer instructions

-counter instructions Program Control

-branching/looping

-immediate inputs/outputs

-fault/interrupt detection Basic Data Handling

-moves

-computation instructions

-boolean instructions

-conversion

Logical

-comparisons Advanced Data Handling

-file instructions

-shift registers/stacks Complex

-PID

-communications

-high speed counters

-ASCII string functions

The reader should be aware that some functions are positive edge triggered (i.e. they only work the scan is active). while most are active any time the input is active. Some examples of edge triggered and non-edge triggered functions are listed below,

Edge Triggered CTU, CTD