Property Import/Export Formats

 

 

 

 

 

41-48

L_11, L_12,

L1x

GRADIUM (Sellmeier)

 

 

… , L_18

Sellmeier chro-

gradient

 

 

 

 

 

 

matic coefficients

 

49-56

L_21, L_22,

L2x

GRADIUM (Sellmeier)

 

 

… , L_28

Sellmeier chro-

gradient

 

 

 

 

 

 

matic coefficients

 

57-64

L_31, L_32,

L3x

GRADIUM (Sellmeier)

 

 

… , L_38

Sellmeier chro-

gradient

 

 

 

matic coefficients

Bulk Scatter Property Format

The format includes 12 header lines, which must be present in the file followed by the actual property data. The tabs or spaces may be used to separate data (Tabs are more convenient when working with spreadsheets).

The tables below describe the format of these files, but the easiest way to learn how to use the Import/Export format is to export a surface property and view it yourself in text format. You may wish to treat the following information as a reference, rather than a tutorial.

Line #

Description

Read for

Format

Import

1

File Header

Yes

TracePro Bulk Scattering Property Data

2

Database File

Ignored

File Name E:\TraceProData\tracepro.mdb

 

Name

 

 

3

TracePro Ver-

Ignored

TracePro Version: 2 1 0

 

sion

 

 

4

Database

Yes

Database Version: 2 1 0

 

Version

 

 

5

Data file was

Ignored

Data generated at 09:32:31 May 06, 2000

 

generated

 

 

6

Blank line

Ignored

 

7

Property

Yes

Name text

 

Name

 

 

8

Property

Yes

Description text

 

Description

 

 

9

User Data

Yes

User flag

 

flag

 

flag

 

 

 

 

 

 

1. Lambda Research Data

 

 

 

(Read Only)

 

 

 

2. User added data

 

 

 

(Read/Write)

10

Type

Ignored

 

11

Blank line

Ignored

 

12

Column

Ignored

Temperature Wavelength

 

Headers

 

Coef 0 Coef 1 Coef 2

 

 

 

Coef 3 Coef 4 Coef 5

 

 

 

 

TracePro 5.0 User’s Manual

7.95

Technical Reference

13+

Scatter data

Yes

Temperature Wavelength and 5 coefficients

 

 

 

Coefficient

 

 

 

1.

Anisotropy (g)

 

 

 

2.

Scattering (1/mm)

 

 

 

3.

Alpha (Gegenbauer Model)

 

 

 

4. unused ( in V2.1 )

 

 

 

5. unused ( in V2.1 )

Last

Save Data

Optional

SAVE-DATA

 

 

 

This may be placed between multiple proper-

 

 

 

ties and is used by the Tools|Data-

 

 

 

base|Import command

Fluorescence Property Format

The format includes 16 header lines, which must be present in the file followed by the property data. Tabs or spaces may be used to separate data (Tabs are more convenient when working with spreadsheets). The tables below describe the format of these files, but the easiest way to learn how to use the Import/Export format is to export a property that is already defined and view it yourself in text format. This will allow you to see exactly what data TracePro exports with each property. Practice by modifying the property name and using the Tools|Database|Import command to add it to your database under the new name.

 

 

Read for

 

Line #

Description

Import

Format

1

File Header

Yes

TracePro Bulk Fluorescence Property Data

2

Database File

Ignored

File Name E:\TraceProData\tracepro.mdb

 

Name

 

 

3

TracePro Ver-

Ignored

TracePro Version: 4 0 0

 

sion

 

 

4

Database

Yes

Database Version: 3 3 0

 

Version

 

 

5

Date file was

Ignored

Data generated at 09:32:31 May 06, 2006

 

generated

 

 

6

Blank line

Ignored

 

7

Property

Yes

Name name

 

Name

 

 

8

Property

Yes

Description text

 

Description

 

 

9

Type Flag

Ignored

 

10

User Data

Yes

User flag

 

Flag

 

flag

 

 

 

1. Lambda Research Data (Read Only)

2. User added data (Read/Write)

7.96

TracePro 5.0 User’s Manual

 

 

 

 

 

Property Import/Export Formats

 

 

 

 

 

 

 

 

11

Blank Line

Ignored

 

 

 

 

12

Peak_Extincti

Yes

Peak Extinction value.

 

 

 

on

 

 

 

 

 

 

 

 

 

 

13

Quantum_Effi

Yes

Quantum Efficiency value

 

 

 

ciency

 

 

 

 

 

 

 

 

 

 

 

 

14

Blank Line

Ignored

 

 

 

 

15

Column

Ignored

Temperature

ExcitationWavelength

 

 

Headers

 

RelativeAbsorption RelativeExcitation

16

Column

Ignored

Temperature

EmissionWavelength

 

 

Headers

 

RelativeEmission

17+

Data

Yes

Column (First Excitation Data)

 

 

 

 

1.

Temperature

 

 

 

 

2.

Excitation Wavelength

 

 

 

 

3.

Relative Absorption

 

 

 

 

4.

Relative Excitation

 

 

 

 

Column (Second Emission Data)

 

 

 

 

1.

Temperature

 

 

 

 

2.

Emission Wavelength

 

 

 

 

3.

Relative Emission

 

Last

Save Data

Optional

SAVE-DATA

 

 

 

 

 

 

This may be placed between multiple proper-

ties and is used by the Tools|Database|Import command

Surface Source Property Format

The format includes 21 header lines, which must be present in the file, followed by the property data. Tabs or spaces may be used to separate data (Tabs are more convenient when working with spreadsheets). The tables below describe the format of these files, but the easiest way to learn how to use the Import/Export format is to export a property that is already defined and view it yourself in text format. This will allow you to see exactly what data TracePro exports with each property. Practice by modifying the property name and using the Tools|Database|Import command to add it to your database under the new name.

 

 

Read for

 

Line #

Description

Import

Format

1

File Header

Yes

TracePro Bulk Fluorescence Property Data

2

Database File

Ignored

File Name E:\TraceProData\tracepro.mdb

 

Name

 

 

3

TracePro Ver-

Ignored

TracePro Version: 5 0 0

 

sion

 

 

4

Database

Yes

Database Version: 3 3 0

 

Version

 

 

 

 

 

 

TracePro 5.0 User’s Manual

7.97

Technical Reference

5

Date file was

Ignored

Data generated at 09:32:31 May 06, 2006

 

generated

 

 

 

6

Blank line

Ignored

 

 

7

Property

Yes

Name name

 

Name

 

 

 

8

Property Cat-

Yes

Catalog catalog

 

alog

 

 

 

9

Property

Yes

Description text

 

Description

 

 

 

10

User Data

Yes

User flag

 

Flag

 

flag

 

 

 

 

 

 

1. Lambda Research Data

 

 

 

(Read Only)

 

 

 

2. User added data

 

 

 

(Read/Write)

11

Spectral Type

Yes

0

= Rectangular

 

 

 

1

= Gaussian

 

 

 

2

= Solar

 

 

 

3

= Table

12

Angular Type

Yes

0

= Lambertian

 

 

 

1

= Uniform

 

 

 

2

= Gaussian

 

 

 

3

= Solar

 

 

 

4

= Table

13

Units

Yes

0

= Radiometric

 

 

 

1

= Photometric

14

Quantity

Yes

0

= Irradiance/Illuminance

 

 

 

1

= Flux

15

Emission

Yes

Total emission of the source

16

Wavelength1

Yes

Min wavelength (Rectangular)

 

 

 

Center wavelength (Gaussian)

17

Wavelength2

Yes

Max wavelength (Rectangular)

 

 

 

1/e2 half-width (Gaussian)

18

Angle1

Yes

Conical angle (Lambertian and Uniform)

 

 

 

x-direction 1/e2 half-width (Gaussian)

19

Angle2

Yes

y-direction 1/e2 half-width (Gaussian)

20

Blank

Ignored

 

 

21

Column

Yes

Temperature Wavelength Polar Angle Azi-

 

Headers

 

muth Angle Emissivity

 

 

 

 

 

7.98

TracePro 5.0 User’s Manual

Соседние файлы в предмете [НЕСОРТИРОВАННОЕ]