ApcSetExternalRefPosition

This command sets the value of the external reference position [137]. The value of Position% is entered in counts, and should be calculated with respect to the same resolution set for the feedback encoder, defined by the command APCSetNumOfTurnsBits(TurnBits%) [14].

Arguments

Pos%

The external reference position in encoder counts.

Return Values

Status%

Value

Meaning

0

The operation failed.

1

The operation succeeded.

Target/ Language Restrictions

This operation is only available on SM-Applications and SM-Applications Lite.

See Also (Position Loop)

  • APCSetPGain

  • APCSetPGainSpeedClamp

  • APCEnableExternalRefSpeed

  • APCDisableExternalRefSpeed

  • APCSetExternalRefSpeed

  • APCEnableExternalRefPosition

  • APCDisableExternalRefPosition

  • APCSetOutputRatioNumerator

  • APCSetOutputRatioDenominator

  • APCSetupOutputChannel

  • APCEnableOutputChannel

  • APCDisableOutputChannel

  • APCWriteOutputChannel

The Advanced Position Controller information given in this help file should only be used as a quick reference guide. For further information please refer to the Advanced Position Controller User Guide which is available via the DPL Editor's Help menu.

________________________________________________________________________________

ApcSetOutputRatioNumerator

This command sets the Position Loop numerator value [133].

Arguments

Num%

The numerator value.

Return Values

Status%

Value

Meaning

0

The operation failed.

1

The operation succeeded.

Target/ Language Restrictions

This operation is only available on SM-Applications and SM-Applications Lite.

See Also (Position Loop)

  • APCSetPGain

  • APCSetPGainSpeedClamp

  • APCEnableExternalRefSpeed

  • APCDisableExternalRefSpeed

  • APCSetExternalRefSpeed

  • APCEnableExternalRefPosition

  • APCDisableExternalRefPosition

  • APCSetExternalRefPosition

  • APCSetOutputRatioDenominator

  • APCSetupOutputChannel

  • APCEnableOutputChannel

  • APCDisableOutputChannel

  • APCWriteOutputChannel

The Advanced Position Controller information given in this help file should only be used as a quick reference guide. For further information please refer to the Advanced Position Controller User Guide which is available via the DPL Editor's Help menu.

________________________________________________________________________________

ApcSetOutputRatioDenominator

This command sets the Position Loop denominator value [133].

Arguments

Den%

The denominator value.

Return Values

Status%

Value

Meaning

0

The operation failed.

1

The operation succeeded.

Target/ Language Restrictions

This operation is only available on SM-Applications and SM-Applications Lite.

See Also (Position Loop)

  • APCSetPGain

  • APCSetPGainSpeedClamp

  • APCEnableExternalRefSpeed

  • APCDisableExternalRefSpeed

  • APCSetExternalRefSpeed

  • APCEnableExternalRefPosition

  • APCDisableExternalRefPosition

  • APCSetExternalRefPosition

  • APCSetOutputRatioNumerator

  • APCSetupOutputChannel

  • APCEnableOutputChannel

  • APCDisableOutputChannel

  • APCWriteOutputChannel

The Advanced Position Controller information given in this help file should only be used as a quick reference guide. For further information please refer to the Advanced Position Controller User Guide which is available via the DPL Editor's Help menu.

________________________________________________________________________________