6 - Sample Edit

Beat Munger

Analysis Results

Swing Control

CPU Meter

Tempo

 

 

 

Grunge

 

 

 

Comb

Adjust

 

 

 

 

 

 

 

Downbeat

Swing

 

 

 

Selection

 

 

 

 

Adjust

 

 

 

8th Note

 

 

 

 

 

 

 

 

Grid

Loop

Stop

Audition

Re-

Process

Boundary

Audition

Loop

Analyze

Sample

Control

 

 

Loop

 

Beat Munger Controls

Analysis Results: This field displays the analyzed tempo and number of beats in the sample. The sample may contain any number of beats and this number will also be displayed in the Loop Controls field.

Tempo Adjust: Adjusts the Tempo of the loop (you knew that) without altering the pitch. The Tempo field defaults to the tempo determined from the analysis.

Swing Adjust & Control: Swing can be modified in both a positive and negative (anti-swing) direction. Negative swing can actually remove swing from a groove.

With Swing set to “Norm” and “0%”, each quarter note is weighted so that the first eighth note takes up 50% of the quarter note and the second eighth note takes up the other 50%. When the swing factor is changed to a positive amount, the first eighth note takes up more of the time and the second eighth note gets the rest. Negative swing lengthens the time spent on the second eighth note

There are four different swing controls.

Fast . . . . . . . . . . . Swings within an eighth note

Norm . . . . . . . . . Swings within an quarter note

Slow . . . . . . . . . . Swings within a half note

Loop Boundary Control: These controls allow you to redefine the start and end points of the loop. For example, you could remove the first beat of a loop or the last bar of a four bar loop. The default setting of this field is determined by the length of the loop.

Downbeat Selection: Sometimes Beat Munger makes a mistake when choosing the proper downbeat and may choose an upbeat instead. This control allows you to correct the mistake. Depending on the source material, several choices may be provided. Use this feature in conjunction with the metronome. You can also use this control to deliberately place the accent on other beats.

238 E-MU Systems

Stereo samples use more CPU resources than mono samples in real-time audition mode.

Note: Final rendering (i.e. pressing OK to actually change the sample data) will always be processed correctly even if real-time playback is choppy.

6 - Sample Edit

Beat Munger

Process Adjust Controls:

Grunge controls the splice crossfade length. This control can make the sound rough, smooth, or “flangy”. Smaller values produce shorter crossfades. Longer crossfades use more CPU resources.

Comb adjusts the distance between splices. This control can be used to keep the groove rhythmically tight, produce comb-filter effects, or create echo-type effects (depending on the source material). Low values can keep the sound from becoming too “fluttery”, especially when shifting the tempo down, but consume more CPU resources.

8th Note Grid: The 8th note grid is a representation of two bars of 8th notes. Individual 8th notes can be turned Off or On. If the loop is longer than 2 measures, the 2-bar grid settings will also be applied to the following measures. The diagram below shows how the 8th note grid corresponds to 8th notes and quarter notes.

4

4

1

8

8th Note Grid

1

4

The time signature can be altered by removing notes from the loop. The diagram below shows a 2-bar loop in 4/4 time being changed into 7/8 time.

7

8th notes removed

8

1

 

 

8

8th Note Grid

 

 

1

 

4

Metronome Level: Adjusts the volume level of the metronome. The metronome is useful in determining the proper downbeats.

CPU Meter: The CPU meter shows the amount of CPU power being used while auditioning in real-time. Extreme settings of the controls with stereo samples may tax the CPU to the point where the audio quality is affected. The CPU meter is a barberpole which moves at a constant rate when everything is running normally. If you see the barberpole stutter or freeze, you may want to select more normal control settings.