vk.com/club152685050Modeling Two-Way Fluid|-Structurevk.com/id446425943Interaction (FSI) Within Fluent

a.Select Linear Elasticity from the Model list.

This model enables structural calculations for the solid cell zone such that the internal load is linearly proportional to the nodal displacement, and the structural stiffness matrix remains constant.

b.Click OK to close the Structural Model dialog box.

23.4.4. Materials

1. Create a new solid material for the flap.

Setup Materials Solid New...

a.Clear the Chemical Formula field.

b.Enter 954 for the Density.

c.Enter 2e+6 for the Youngs Modulus.

d.Enter 0.35 for the Poisson Ratio.

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

770

of ANSYS, Inc. and its subsidiaries and affiliates.

vk.com/club152685050 | vk.com/id446425943

Setup and Solution

e. Click Change/Create and close the Create/Edit Materials dialog box.

 

23.4.5. Cell Zone Conditions

1.Set up the cell zone conditions for the solid zone associated with the flap (solid.5).

Setup Cell Zone Conditions solid.5 Edit...

a.Select solid-1 from the Material Name drop-down list.

b.Click OK to close the Solid dialog box.

23.4.6. Boundary Conditions

You must ensure that the boundary conditions are appropriately defined for every wall that is immediately adjacent to the solid zone.

1.Set the boundary conditions for flap_attach, which is located where the flap attaches to the duct. You will define it as being fixed (that is, undergoing no displacement).

Setup Boundary Conditions flap_attach Edit...

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

 

of ANSYS, Inc. and its subsidiaries and affiliates.

771

vk.com/club152685050Modeling Two-Way Fluid|-Structurevk.com/id446425943Interaction (FSI) Within Fluent

a.Click the Structure tab.

b.Retain the default settings for the displacement boundary conditions (that is, Node X-Displacement from the X-Displacement Boundary Condition drop-down list with 0 for the X-Displacement, and so on).

c.Click OK to close the Wall dialog box.

2.Set the boundary conditions for all of the two-sided walls (that is, the wall / wall-shadow pairs) between the solid and fluid cell zones. In this case there is one pair of walls, which represent the outer surface of the flap.

a.Set the boundary conditions for flap_wall-shadow.

Setup Boundary Conditions flap_wall-shadow Edit...

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

772

of ANSYS, Inc. and its subsidiaries and affiliates.

vk.com/club152685050 | vk.com/id446425943

Setup and Solution

Note that the Adjacent Cell Zone for this wall is fluid.4, which is the fluid zone. The side of the wall / wall-shadow pair that is immediately adjacent to the fluid does not require any settings in the Structure tab, and so this tab is not available.

i.Retain the default settings in the Momentum tab.

ii.Click OK to close the Wall dialog box. b. Set the boundary conditions for flap_wall.

Setup Boundary Conditions flap_wall Edit...

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

 