Setup and Solution

a.Enter nozzle for Zone Name.

This name is more descriptive for the zone than wall-2.

b.Click the Thermal tab.

i.Retain the default selection of Heat Flux in the Thermal Conditions list.

ii.Retain the default value of 0 for Heat Flux, so that the wall is adiabatic.

c.Click OK to close the Wall dialog box.

13.5.7. Initial Reaction Solution

You will first calculate a solution for the basic reacting flow neglecting pollutant formation. In a later step, you will perform an additional analysis to simulate NOx.

1. Solution Solution Methods...

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

 

of ANSYS, Inc. and its subsidiaries and affiliates.

459

vk.com/club152685050Modeling Species Transport| vkand.com/id446425943Gaseous Combustion

Retain the default selections.

2.Ensure the plotting of residuals during the calculation.

Solution Reports Residuals...

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

460

of ANSYS, Inc. and its subsidiaries and affiliates.

vk.com/club152685050 | vk.com/id446425943

Setup and Solution

a.Ensure that Plot is enabled in the Options group box.

b.Click OK to close the Residual Monitors dialog box.

3.Initialize the field variables.

Solution Initialization

a.Retain the default Hybrid initialization method and click Initialize to initialize the variables.

4.Save the case file (gascomb1.cas.gz).

File Write Case...

a.Enter gascomb1.cas.gz for Case File.

b.Ensure that Write Binary Files is enabled to produce a smaller, unformatted binary file.

c.Click OK to close the Select File dialog box.

5.Run the calculation by requesting 200 iterations.

Solution Run Calculation Advanced...

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

 

of ANSYS, Inc. and its subsidiaries and affiliates.

461

vk.com/club152685050Modeling Species Transport| vkand.com/id446425943Gaseous Combustion

a.Enter 5 for the Timescale Factor.

The Timescale Factor allows you to further manipulate the computed Time Step calculated by ANSYS Fluent. Larger time steps can lead to faster convergence. However, if the time step is too large it can lead to solution instability.

b.Enter 200 for Number of Iterations.

c.Click Calculate.

6.Save the case and data files (gascomb1.cas.gz and gascomb1.dat.gz).

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information