Note that the Adjacent Cell Zone for this wall is solid.5, which is the solid zone. The side of the wall / wall-shadow pair that is immediately adjacent to the solid does require structural settings (that is, displacement boundary conditions).

i.Click the Structure tab.

ii.Select Intrinsic FSI from the X- and Y-Displacement Boundary Condition drop-down lists.

This specifies that the displacement results from pressure loads exerted by the fluid flow on the faces. This setting is only available for two-sided walls.

iii.Click OK to close the Wall dialog box.

23.4.7. Dynamic Mesh Zones

For two-way FSI simulations, you must define dynamic mesh properties to allow the mesh to handle the deformation of the solid zone.

Domain Mesh Models Dynamic Mesh...

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

774

of ANSYS, Inc. and its subsidiaries and affiliates.

vk.com/club152685050 | vk.com/id446425943

Setup and Solution

1.Enable the Dynamic Mesh option.

2.Make sure that the Smoothing option is enabled in the Mesh Methods group box, and click the Settings...

button to open the Mesh Method Settings dialog box.

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

 

of ANSYS, Inc. and its subsidiaries and affiliates.

775

vk.com/club152685050Modeling Two-Way Fluid|-Structurevk.com/id446425943Interaction (FSI) Within Fluent

a.Select Linearly Elastic Solid from the Method list.

b.Click OK to close the Mesh Method Settings dialog box.

3.Retain the default settings in the Options group box (that is, with the options disabled). These options are not supported for FSI simulations, except for Implicit Update. The Implicit Update option may be required for more complex cases in which the stability of the FSI simulation may be an issue, but for a simple case such as this one, it is not required.

4.Click the Create/Edit... button to open the Dynamic Mesh Zones dialog box.

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

776

of ANSYS, Inc. and its subsidiaries and affiliates.

vk.com/club152685050 | vk.com/id446425943

Setup and Solution

a.Select po.3 (the pressure outlet) from the Zone Names drop-down list, select Stationary from the Type list, and click Create. This ensures the boundary zone does not deform.

b.In a similar manner, create stationary dynamic zones for the other boundary zones that are not deforming: symmetry.2, velocity_inlet.1, and wall.

c.Select flap_wall-shadow (the side of the wall / wall-shadow pair that is immediately adjacent to the fluid) from the Zone Names drop-down list, select Intrinsic FSI from the Type list, and click Create. This specifies that the wall / wall-shadow pair deforms according to the deformation of the adjacent solid zone.