c.From the Cell Zones selection list, select all zones.

d.In the Create group box, enable Report File, Report Plot and Print to Console.

e.Click OK to save the volume report definition settings and close the Volume Report Definition dialog box.

f.Rename the report output file.

Solution Monitors Report Files max_temp-rfile Edit...

i.Enter max-temp-1c.out for Output File Base Name.

ii.Click OK to close the Edit Report File dialog box.

g.Modify the axis attributes by setting the Precision to 0 for the X axis and to 2 for the Y axes (in a manner similar to the surface plot definition).

h.Click OK.

5.Save the case file.

File Write Case...

25.4.4.6. Obtaining Solution

1.Initialize the field variables using the Standard Initialization method.

Solution Initialization

a.Retain the selection of the Standard method (Initialization group).

b.Click Initialize.

You do not need to modify Initial Values in the Solution Initialization task page, because these values are not used for initialization. The ANSYS Fluent solver automatically computes the initial condition for UDS0 and UDS1.

2.Run the simulation.

Solution Run Calculation

a.Set Time Step Size to 30 seconds and No. of Time Steps to 100.

b.Click Calculate.

The residual plot, the report for voltage at the positive tab and the history of the maximum temperature in the domain are shown in Figure 25.5: Residual History of the Simulation (p. 841), Figure 25.6: Report Plot of Discharge Curve at 1 C (p. 841), and Figure 25.7: History of Maximum Temperature in the Domain (p. 842), respectively.

 

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

840

of ANSYS, Inc. and its subsidiaries and affiliates.

vk.com/club152685050 | vk.com/id446425943

Setup and Solution

Figure 25.5: Residual History of the Simulation

Figure 25.6: Report Plot of Discharge Curve at 1 C

Release 2019 R1 - © ANSYS,Inc.All rights reserved.- Contains proprietary and confidential information

 

of ANSYS, Inc. and its subsidiaries and affiliates.

841

Соседние файлы в предмете Информатика